How to use the water replenishment valve of the wall-mounted boiler
Wall-hung boilers are common equipment in modern home heating systems, and the water replenishment valve is an important part of the wall-hung boiler. Its correct use is directly related to the operating efficiency and safety of the wall-hung boiler. This article will introduce in detail the use, precautions and answers to frequently asked questions about the wall-hung boiler water replenishment valve to help users better operate and maintain the wall-hung boiler.
1. The function of the water replenishment valve of the wall-mounted boiler

The main function of the water replenishment valve is to add water to the heating system of the wall-mounted boiler to ensure that the water pressure in the system remains within the normal range. When the system water pressure is too low, the water replenishment valve can replenish water manually or automatically to prevent the wall-hung boiler from functioning normally due to insufficient water pressure.
2. How to use the wall-mounted boiler water replenishing valve
The following are the detailed steps for using the water replenishment valve of the wall-hung boiler:
| steps | Operating Instructions |
|---|---|
| 1 | Check the water pressure gauge of the wall-mounted boiler to confirm whether the current water pressure is lower than the normal range (usually 1-1.5bar). |
| 2 | Turn off the power supply to the wall-hung boiler to ensure safe operation. |
| 3 | Locate the fill valve (usually on the bottom or side of the boiler). |
| 4 | Turn the handle of the water replenishment valve counterclockwise to slowly open the water replenishment valve. |
| 5 | Observe the water pressure gauge. When the water pressure reaches 1-1.5bar, turn the handle of the water replenishment valve clockwise to close the water replenishment valve. |
| 6 | Restart the wall-mounted boiler and check whether the system is operating normally. |
3. Precautions when using the water replenishment valve
When using the water replenishment valve, you need to pay attention to the following points:
| Things to note | Description |
|---|---|
| 1 | Do not overfill the water during the water replenishment process to avoid excessive water pressure causing leakage or damage to the system. |
| 2 | The water replenishment valve must be completely closed after use to prevent continued water replenishment. |
| 3 | Regularly check whether the water replenishing valve is leaking. If there is leakage, replace it in time. |
| 4 | If the water pressure drops frequently, there may be a leak in the system that needs to be checked by a professional. |
4. Frequently Asked Questions
The following are common problems and solutions that users may encounter when using the water replenishment valve:
| question | Solution |
|---|---|
| The water replenishment valve cannot be opened | Check whether the water replenishment valve is rusted or damaged and replace it with a new one if necessary. |
| Water pressure is still too low after replenishing water | Check the system for leaks or contact a professional for repair. |
| Water replenishment valve leaking | Close the water replenishing valve, check whether the sealing ring is intact, and replace it if necessary. |
5. Summary
The correct use of the wall-mounted boiler water replenishment valve is the key to ensuring the normal operation of the heating system. Through the introduction of this article, users should be able to master the basic operation methods, precautions and solutions to common problems of the water replenishment valve. If you encounter a problem that cannot be solved, it is recommended to contact professional maintenance personnel in time to avoid equipment damage or safety hazards caused by improper operation.